摘要
目的:本临床试验旨在比较即刻种植体位于游离龈下4 mm与6 mm处,在1年后的治疗效果。
材料与方法:70枚平台转换、莫氏锥度锥形连接、颈部加工宽度1 mm的种植体,在磨牙或前磨牙区拔牙后立即以无瓣法植入。35枚种植体置于颊侧龈缘下4 mm(对照组),另外35枚置于龈缘下6 mm(试验组)。所有种植体位点均使用同种异体骨替代品进行植骨,并佩戴椅旁制作的个性化愈合基台。4个月后,使用最终螺丝固位氧化锆修复体进行修复。在最终修复体戴入时(T1)和1年后(T2)测量放射学边缘骨丧失(MBL)。在1年随访预约时(T2)记录种植体周围临床参数(探诊深度[PD]、探诊出血[BOP]和菌斑指数[PI])。
结果:1年随访后共评估70枚种植体(对照组35枚,试验组35枚)。试验组在T1(平均值±标准差:0.11 ± 0.32 vs. 0.76 ± 0.68 mm)和T2(0.12 ± 0.23 vs. 0.54 ± 0.49 mm)时的MBL均显著低于对照组(p < 0.001)。对照组的PD均值为3.46 ± 0.74,试验组为3.49 ± 1.20,p值为0.890。两组的PI和BOP也相似:对照组PI为11%,试验组为8%(p = 0.551);对照组BOP为13%,试验组为7%(p = 0.214)。
结论:位于颊侧中线龈下6 mm的即刻种植体比位于龈下4 mm的即刻种植体显示出显著更少的短期(长达1年)边缘骨丧失。
原文摘要
PURPOSE: This clinical trial was carried out to compare the outcomes of immediate implants positioned 4 mm below free gingival margin versus deeper placement of 6 mm after a period of 1 year.
MATERIALS AND METHODS: Seventy platform-switching implants with a Morse taper conical connection and 1 mm of machined neck were placed in a flapless approach in the molar or premolar region immediately after tooth extraction. A total of 35 implants were positioned 4 mm below the buccal gingival margin (control group), and another 35 were placed 6 mm below the gingival margin (test group). All implant sites were grafted with an allogenic bone substitute and received individual healing abutments (IHAs) made chairside. After 4 months, the implants were restored with final screw-retained zirconia restorations. Radiographic marginal bone loss (MBL) was measured at the delivery of the final restoration (T1) and after 1 year (T2). Peri-implant clinical parameters (probing depth [PD], bleeding on probing [BOP], and plaque index [PI]) were recorded at 1-year follow-up appointment (T2).
RESULTS: In total, 70 implants were evaluated after 1 year of follow-up (35 control and 35 test groups). The test group showed significantly lower (p < 0.001) MBL than the control group at both T1 (mean ± standard deviation: 0.11 ± 0.32 vs. 0.76 ± 0.68 mm) and T2 (0.12 ± 0.23 vs. 0.54 ± 0.49 mm). The PD mean was 3.46 ± 0.74 in the control group and 3.49 ± 1.20 in the test group, with a p-value of 0.890. PI and BOP were also similar in both groups: PI-11% for the control and 8% for the test groups (p = 0.551), BOP-13% for the control and 7% for the test groups (p = 0.214).
CONCLUSIONS: Immediate implants placed 6 mm below the mid-buccal gingival level showed significantly less short-term (up to 1 year) MBL than immediate implants placed 4 mm below the gingiva.
出处
Journal of prosthodontics 2026;35(7):1008-1020. DOI: 10.1111/jopr.70189.
本页仅收录摘要与出处,不存储全文(合规要求)。
